6 Amps
(6000mA) Continuous Balancing!
Battery
AH 50-1000!
Unlimited
Cell Count
LiFePO4-LiMn2O4-NiMH-Li-Ion-Polymer-Lithium
Balances
during charge, discharge, and storage
3V 1S
Battery Voltage-Amperage
Balancers/Equalizers
With LED Indicator Lights
|
We recently expanded our
line of Balancers/Equalizers to include ones with LED Indicator Lights. They
perform the same tasks as the old Balancers like keeping your batteries voltage
difference within 10mV and prolonging battery lifespan by 2-3 times.
Additionally it has a
lighting system to indicate the status of your batteries. There are two LED
indicators on the balancer which tells you the status of your batteries (charge
or discharge) and status of the balancer (cut-off or working or faulty).
Cell balancing works
similar to cups with different amounts of water in each. A balancer that is in
the process of equalizing batteries is like a pump that is attached from one
cup to another. With the pumps, all the cups will have the same level of water.
When a pack of batteries
reaches a specified charge cutoff voltage then the charger will shut off. If
one cell in a pack reaches that voltage before other cells reach a full charge
it will cause the charger to shut off - prematurely denying the balance of the pack
a full charge.
Conversely, when the
weakest cell in a pack reaches its discharge cutoff voltage it will show as the
discharge point and shut down the pack prematurely - thereby denying the user
the balance of energy the other cells have stored.
These battery equalizers
prevent this from happening. This yields up to 30% more power and will extend
the life of the battery pack.
Ask us why we believe these
battery balancers are better then a traditional Battery Management System (BMS)!
QUANTITY
PRICING
|
|
1-3
|
$23.50
|
4-11
|
$22.75
|
12-23
|
$21.50
|
24-47
|
$21.00
|
48-95
|
$20.50
|
96-199
|
$20.00
|
200-499
|
$19.75
|
500+
|
$19.25
|
Features:
§
Balance
current: 1A balance current when the voltage difference is 500mV
§
Balance
accuracy: The voltage difference is <20mV after balancing
§
Working
efficiency: >94% (at 1A)
§
Power
consumption: After finishing balancing, the balance current is <20mA
§
Maximum
acceptable voltage: DC 1,000V
§
Working
temperature: -40F~176F (-40C~80C)
§
Storage
temperature: -40F~212F (-40C~100C)
§
Relative
humidity: 45%~90%
§
Parasitic current drain: 1 watt per day
§
Series
modules
·
Modules
may work with 3, 4, 5, 6, or 8 batteries in series (AKA 3S, 4S, 5S, 6S, or 8S)
·
Does
not come with the wiring to connect to the batteries
Example:
A
144v pack of 48 cells,
20
in the front and 28 in the back
can
use 8S+8S+4S in front
and 8S+8S+8S+4S in the back.
No comments:
Post a Comment